Battery Technical Specification about Off Grid 10KWh All-in-one ESS Battery with Inverter AC Output 5KW Certified by UL & CE
No. | Item | Specification | Remarks |
1 | Battery Pack | 16S2P | Cell 105Ah |
2 | Energy | 10.24kwh | |
3 | Rated Capacity | 200Ah@25℃ 0.3C | |
4 | Minimal Capacity | 198Ah@25℃ 0.3C | |
5 | Rated Voltage | 51.2V | |
6 | Charge Voltage | 57.6V | |
7 | Charge Mode | CC/CV | |
8 | Discharge Cut Off Voltage | 46.4V | |
9 | Rated Charge Current | 75A @25℃ | |
10 | Max Charge Current | 100A @25℃ | |
11 | Rated Discharge Current | 75A | |
12 | Max Discharge Current | 100A | |
13 | Internal Resistance | ≤30mΩ @AC 1kHz | |
14 | Working Temperature | Charge:0℃ to 45℃ Discharge:-20℃ to 55℃ Storage:0℃ to 40℃ |
|
15 | Communication | RS485 | |
16 | Screen | LCD Screen | |
17 | Shell Material | Stainless steel | |
18 | Dimensions | 1100*520*195 (L*W*H) | |
19 | Weight | ≈100kg | |
20 | Protection Class | IP21 | |
21 | Safety Certificate | UN38.3/MSDS/UL |
Inverter Specification
No. | Item | Technical Parameters | Remarks |
1 | AC Input Voltage | 220V/230Vac | EU standard / Off grid |
2 | AC Input Voltage Range | APL DG model:90Vac-280Vac; UPS City Power:170Vac-280Vac; |
|
3 | AC Charge Current | Max 60A | |
4 | AC Charge Efficiency | >95% | |
5 | Conversion time (bypass and inversion) | 10mS | |
6 | Output voltage wave | pure sine wave | |
7 | AC output rated voltage | 230Vac | |
8 | Rated output power | 5000W | |
9 | Peak power | 10000VA | |
10 | Maximum efficiency | 92% | |
11 | No-load power consumption | ≤50W | |
12 | PV input voltage range | 60-145Vdc | |
13 | Maximum PV input current | 50A | |
14 | Maximum PV input power | 4400W | |
15 | Maximum PV charging current | 80A | |
16 | Rated battery input voltage | 48V | |
17 | Battery voltage range | 40Vdc-60Vdc | |
18 | Wi-Fi Module | Optional | |
19 | Safety Certificate | CE/EN61000/UL |
BMS Specification
Item | Test item | Specifications | Units | ||||
Min Value |
Typical Value |
Max Value |
|||||
Voltage | Over charge detection voltage | 3.65 | 3.70 | 3.75 | V | ||
Over charge protection delay time | 500 | 1000 | 2000 | mS | |||
Over charge detection release voltage | 3.40 | 3.45 | 3.50 | V | |||
Over discharge detection voltage | 2.450 | 2.500 | 2.550 | V | |||
Over discharge protection delay time | 500 | 1000 | 2000 | mS | |||
Over discharge detection Release voltage | 2.650 | 2.700 | 2.750 | V | |||
Current | Over discharge current detection | 110 | 120 | 130 | A | ||
Over discharge protection delay time | 800 | 1000 | 1500 | mS | |||
Continuous charging current | — | 100 | — | A | |||
Continuous discharge current | — | 100 | — | A | |||
Short protection | Short-circuit protection delay time | 200 | 330 | 800 | uS | ||
Short circuit protection recovery | Disconnect load | ||||||
Equilibrium function | Equilibrium voltage | 3.425 | 3.45 | 3.475 | V | ||
Equalizing current | 30 | mA | |||||
Interior resistance | / | / | 10 | 20 | mR | ||
Temperature | Working temperature | -20 | 60 | ℃ | |||
Storage temperature | -40 | 65 | ℃ |