Discharge Current | 100A 200A |
---|---|
Discharge Contact Protection Value | 7~13S |
Main Circuit Conductance Impedance | 10mΩ |
Charging Current (Interval) | 100A 200A |
Charging Contact Protection | |
Charging Voltage | Ternary Charging Combination Voltage x 4.2V |
Lithium Iron Phosphate Combination Voltage x 3.6V | |
Overcharge protection | Balanced voltage |
NCM4.25±0.03 V | Voltage: NCM4.0±0.03 V / LFP 3.30±0.03 V |
LFP 3.75±0.05 V | Voltage differential turn-on: 15 mV |
Protection delay: 2000 ms | Balancing current: ≤200mA |
Recovery voltage: NCM4.15±0.05 V / LFP 3.60±0.05 V | |
Overdischarge voltage protection | Overdischarge current protection |
Protection: NCM2.8±0.1 V / LFP: 2.5±0.1 V | Overcurrent protection: 7~13S |
Protection Delay: 2000 ms | Recovery condition: Automatic recovery after a delay of 32 seconds |
Recovery Voltage: NCM3.0±0.1 V / LFP: Charging recovery | |
Short-circuit protection | Temperature control protection |
Detection Delay: 400~800 µs | Discharge high-temperature protection: 90±5°C |
Release conditions: Disconnect the load, and restore after a 5-second delay. | Discharge high-temperature release temperature: 70±5°C |
Self-discharge | Working Temperature |
Work power consumption: ≤20 mA | Temperature range: -30°C / +75°C |
Standby power consumption: ≤3 mA | |
Size | 202*76*18mm |